{"product_id":"433mhz-30w-signal-booster-high-output-two-way-amplifier-for-extended-coverage-smart-metering-remote-telemetry-industrial-iot-networks","title":"433MHz 30W Signal Booster – High-Output Two-Way Amplifier for Extended-Coverage Smart Metering, Remote Telemetry \u0026 Industrial IoT Networks","description":"\u003ch2 align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cp class=\"p\" align=\"justify\"\u003e\u003cspan\u003eExtending coverage in the 433MHz ISM band often requires more than antenna changes alone. This \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e433MHz 30W Signal Booster\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e raises both uplink and downlink signal levels, allowing smart metering, remote telemetry, industrial IoT, and remote control systems to operate reliably at greater distances and through more challenging environments. It provides \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e20dB TX gain\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e18dB RX gain\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e in a \u003c\/span\u003e\u003cb\u003e\u003cspan\u003ecompact aluminum housing\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e, with \u003c\/span\u003e\u003cb\u003e\u003cspan\u003eSMA female connectors\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e and a \u003c\/span\u003e\u003cb\u003e\u003cspan\u003ewide 12-24V DC input\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e for direct integration into existing radio modems, gateways, and field equipment. The \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e5.5*2.1mm power socket\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e matches common industrial and portable power supplies. When additional RF margin is needed to stabilize marginal 433.05-434.79MHz links, this booster delivers \u003c\/span\u003e\u003cb\u003e\u003cspan\u003ebalanced two-way amplification\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e without redesigning the RF chain.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eTypical Applications\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"p\" align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eSmart Metering \u0026amp; AMI Networks:\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e Increase two-way link margin for utility meters and automatic reading infrastructure.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p\" align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eRemote Telemetry \u0026amp; SCADA:\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e Reinforce uplink and downlink signals for distant monitoring and control points.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p\" align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eIndustrial IoT Sensor Networks:\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e Extend reliable coverage for low-power sensors, actuators, and controllers.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p\" align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eUAV Remote Control \u0026amp; Telemetry:\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e Improve 433MHz command and telemetry stability in extended-range operations.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p\" align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eWireless Alarm \u0026amp; Automation Systems:\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e Enhance signal reliability for security panels, access control, and smart building devices.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p\" align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eLicensed 433MHz Field Testing:\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e Support higher two-way output for RF experimentation and validation.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cdiv align=\"center\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eWorking Frequency\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003e433.05-434.79MHz (center 433.92MHz)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eOutput Power\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003e30W(45dBm)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eTX Gain (S21)\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003e20dB\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eRX Gain (S21)\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003e18dB\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eDC Supply\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003e12-24V\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eConnector\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003eSMA female\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eSize\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003e118*59*17.5mm\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003e0.27Kg\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35.6800%\" valign=\"center\" style=\"width: 33.2658%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003ePower Socket\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64.3000%\" valign=\"center\" style=\"width: 66.7342%;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"justify\"\u003e\u003cspan\u003e5.5*2.1mm\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eKey Advantages\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cp class=\"p\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003e30W-Class Output for Extended Coverage.\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e This \u003c\/span\u003e\u003cb\u003e\u003cspan\u003eSignal Booster\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e delivers \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e30W(45dBm)\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e with \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e20dB TX gain\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e18dB RX gain\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e, adding substantial link margin for metering, telemetry, and industrial IoT networks operating near the edge of coverage.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eBalanced Two-Way Gain.\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e With matched TX and RX amplification, the booster improves both outbound commands and inbound data, which is essential for polling, acknowledgements, and two-way control in remote metering and telemetry systems.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\" align=\"justify\"\u003e\u003cb\u003e\u003cspan\u003eIndustrial-Grade Integration.\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e The \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e12-24V DC input\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cb\u003e\u003cspan\u003eSMA female connector\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e5.5*2.1mm power socket\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e118\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan class=\"15\"\u003e*\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e59\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan class=\"15\"\u003e*\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e17.5mm aluminum housing\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e weighing \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e0.27Kg\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e simplify deployment in pole-mounted, portable, and industrial installations.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 align=\"justify\"\u003e\n\u003cb\u003e\u003cspan\u003eWhat's in the Box\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"p\" align=\"justify\"\u003e\n\u003cspan\u003e1 × 433MHz 30W Signal Booster\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MODVOR","offers":[{"title":"Default Title","offer_id":54502202081598,"sku":null,"price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/5207\/6862\/files\/6_ff52c233-6d0b-4619-92f3-cf8719596851.jpg?v=1790213730","url":"https:\/\/modvor.com\/products\/433mhz-30w-signal-booster-high-output-two-way-amplifier-for-extended-coverage-smart-metering-remote-telemetry-industrial-iot-networks","provider":"MODVOR","version":"1.0","type":"link"}